HIGH END LABORATORY EQUIPMENT DESCRIPTION PROFILE
Projector PJ-A3000 Series
PROJECTOR PJ -A3000 SERIES
Model: PJ-A3005D-50 Mitutoyo, Japan
Specification |
Learning Objective |
Learning Outcome |
Tools Required |
Safety/Precaution |
This is a multi-purpose Profile Projector |
1.Care & Operation |
Understanding |
Soft Lens Cleaning Cloth |
Apron |
for factory inspection use. It can perform |
of Profile Projector |
Operation of Profile |
|
Soft Gloves |
precision measurement of work piece |
2. Magnification |
Projector |
Lens Cleaner |
Shoes |
dimension, contours and surface feature.
|
Requirement 3. Dimension & |
Knowledge of |
Magnifying Lens |
|
Code No. 302-704-1E (PJ-A3005D-50) |
Angle Measuring |
Dimension & Angle |
|
|
X axis stroke 50mm, Y axis stroke 50mm |
Techniques |
Measuring Methods |
Operation Guide Book |
|
Maximum Work Piece Height 123mm
|
3. Result Analysis
|
Hands on Industrial |
|
|
Magnification Error ± 0.1mm (in 100mm) |
|
Experience |
|
|
Magnification Error ± 0.14mm (in |
For: |
|
|
|
140mm) |
Diploma |
Research and |
|
|
|
B.Sc. / M.Sc. |
Analysis |
|
|
Resolution for coordinate measurement |
B.Tech /M.Tech |
|
|
|
(X, Y counter)-0.001mm
|
Research (PhD)
|
|
|
|
PROFILE PROJECTOR PJ-A3000 SERIES
Ashing Furance
ASHING FURNACE
Model: AAF 11/7 Make: CARBOLITE Limited, UNITED KINGDOM
Specification
|
Learning Objective
|
Learning Outcome
|
Tools Required |
Safety Precaution |
The ash furnace provides optimum combustion |
1.Sample Preparation of |
Understanding Ash Content in Coal |
Grinder |
Shoes |
conditions to ensure complete combustion of |
Coal for Ash Analysis as |
|
Pallet Press |
Apron |
the sample. The necessarily high airflow is |
per Standard |
Evaluate & Grading Coal (Ash |
Crucible |
Hand Gloves |
preheated before entering the chamber. The silicon carbide tiles are provided to protect the heating elements from the accumulation of |
2.Operation & Care of Furnace 3.Grading & Reporting |
Percentage) Write a Professional Scientific Report
|
Rack Plate Tong
|
|
carbon that can occur during applications.
Other heat treatment work can be done in AAF 11/7 furnace at a maximum operating temperature of 1100°C ± 5⁰C Make: CARBOLITE Limited, Parsons Lane, Hope, Hope Valley,533 6RB, UNITED KINGDOM GERO GmbH & Co. KG, Hesselbachstr,15, 75242 Neuhausen, GERMANY |
Ash Content in Coal
|
Hands on Industrial Experience,
|
|
|
ASHING FURNACE
Volatile Matter Furnace
VOLATILE MATTER FURNACE
Model: VMF 10/6 Make: CARBOLITE Limited, UNITED KINGDOM
Specification
|
Learning Objective
|
Learning Outcome
|
Tools Required
|
Safety Precaution |
The VMF 10/6 designed for testing the |
1.Sample Preparation as per |
Understand Volatile Matter in Coal |
Grinder |
Shoes |
volatile matter of coal according to ISO |
Standard |
|
Pallet Press |
Apron |
562:2010 Maximum Temperature1000⁰C Type Front loading Maximum Continuous Operating Temperature 900⁰C Heat-up time 20 minutes to 900°C Dimensions: Internal H x W x D : ( mm) 100 x 210 x 260 Dimensions: External H x W x D (mm) 655 x 435 x 610 Max power (W) 3000 Thermocouple type K Make: CARBOLITE Limited, Parsons Lane, Hope, Hope Valley,533 6RB, UNITED KINGDOM GERO GmbH & Co. KG, Hesselbachstr,15, 75242 Neuhausen, GERMANY
|
2.Care & Operation of Furnace & Accessories
3. Calculate Volatile Matter Percentage
For: Diploma B.Sc. /M.Sc. B.Tech /M.Tech Research (PhD)
|
Evaluate Volatile Matter in Coal
Write a Scientific & Professional Report for Volatile Matter in Coal
Hands on Industrial Experience
|
Crucible Rack Plate Tong
|
Hand Gloves
|
VOLATILE MATTER FURNACE
Rockwell Hardness Testing Machine-Digital
ROCKWELL HARDNESS TESTING MACHINE -DIGITAL
Model: A300 (HR 320MS) Mitutoyo, Brazil
Specification |
Learning Objective |
Learning Outcome |
Tools Required |
Safety Precaution |
The Hardness Tester is designed to test the |
1.Sample |
Safe Operation of |
Weight: |
Shoes |
hardness of general steel, metals and some |
Preparation |
Hardness Tester |
15,30,45,60,100,150 grams |
Apron |
non metals to the Rockwell Hardness Test |
2.Operation of |
|
|
Hand Gloves |
Method using A, B, C scale. |
Hardness Tester |
Knowledge of |
Diamond Indenter |
|
|
3. Result Analysis |
Hardness Scales |
Steel Ball Indenter 1/6 inch |
|
Make: Mitutoyo Sul Americana Ltda, Av, |
|
|
Flat Anvil -64mm |
|
Joao Carloos da Silva Borges,1240-CEP |
|
Hands on Industrial |
HRC Test Block-30 & |
|
04726-002 Santo Amaro- Sao Paulo-SP, |
For: |
Experience |
60HRC, 90HRB, 65HR30N, |
|
BRASIL |
Diploma |
|
& 70HR30T |
|
|
B.Sc. / M.Sc. |
Research and |
AC Adapter |
|
|
B.Tech /M.Tech Research (PhD)
|
Analysis
|
|
|
ROCKWELL HARDNESS TESTING MACHINE -DIGITAL
Analytical Sieve Shaker
ANALYTICAL SIEVE SHAKER
Model: AS 200 digital Retsch GmbH, Germany
Specification
|
Learning Objective
|
Learning Outcome
|
Tools Required
|
Safety Precaution |
AS 200 have digital time display, interval |
1.Standard Sample |
Understand Grain Size & |
1. Vibration Deck |
Shoes |
operation and analogue adjustment with optical |
Preparation |
Mesh Size |
2. Sieve Sizes |
Apron |
monitoring of the vibration height. (vibration |
2.Arranging Sieves in a |
|
45µm |
Hand Gloves |
height adjustable from 0 to 3mm). |
Deck |
Familiarization with ASTM |
65µm |
|
|
3.Cleaning, Care & |
& ISO Standards |
125µm |
|
Electromagnetic drive |
Operation of SIEVE |
|
250µm |
|
3 Dimensional Motion of Projections |
SHAKER |
Research & Development |
500µm |
|
3000 Vibration / minute |
4. Result Analysis & |
and Quality Control of Raw |
1.0mm |
|
Quiet Running (65 dB)
|
Report Writing
|
Materials
|
2.0mm 4.0mm |
|
Application: |
For: |
Hands on Industrial |
3. Collecting Pan |
|
Separation, fractioning, |
Diploma |
Production Experience |
4. Wet pan |
|
Particle Size Determination |
B.Sc. / M.Sc. |
|
|
|
Feed material: Powders, Bulk Materials, |
B.Tech /M.Tech |
Independent Thinking |
|
|
Slurry/Suspensions Measuring range: 20μm to 25mm Maximum Batch Feed Capacity: 3Kg Maximum No. of Fractions: 9/17 Maximum Mass of Sieve Stack: 4Kg Make: Retsch GmbH, Retsch-Alle 1-5, 42781 Haan,Germany |
Research (PhD)
|
|
|
|
ANALYTICAL SIEVE SHAKER
Parr Isoperibol Bomb Calorimeter
PARR ISOPERIBOL BOMB CALORIMETER
Model: 6200 with 1108P Vessel PARR INSTRUMENT COMPANY, USA
Specification |
Learning Objective |
Learning Outcome |
Tools Required |
Safety/Precaution |
|
|
|
|
|
The temperature-controlled water |
1.Sample |
Cleaning, Care & |
1108P Oxygen |
Shoes |
jacketed calorimeter with a built-in |
Preparation (solid, |
Operation of a Calorimeter |
Combustion vessel |
Apron |
circulating system and an electric heater |
liquid) |
|
Oval Bucket – 1 No. |
Hand |
calorimeter with Automatic |
2.Loading & |
Test Procedure for |
Ignition Thread test |
Gloves |
Microprocessor Control. It has a built-in |
Operation |
Calorific Value of a |
Heat wire, |
|
automatic system for charging the |
Procedure of |
Substance |
Benzoic acid pellets |
|
combustion vessel with oxygen. It is |
Bomb Calorimeter |
|
Sample crucibles – |
|
equipped with high precision electronic |
3. Result Analysis |
Understand & Evaluate |
PK/6 |
|
thermometer. |
|
Calorific Value |
|
|
A variety of vessels can be used for testing |
|
|
Oxygen Gas Cylinder |
|
samples releasing from 52 calories to |
For: |
Write a Professional and |
47 Liters with Gas |
|
12,000 calories per test.
|
Diploma B.Sc. / M.Sc. |
Scientific Report
|
Regulator
|
|
Test Hour: 4-7 as equipped |
B.Tech /M.Tech |
Hands on Industrial |
|
|
Operator time per test: 6 min |
Research (PhD) |
Experience |
|
|
Precision / Repeatability (%RSD): 0.05- 0.10% |
|
Analytical and Critical |
|
|
Temperature Resolution: 0.0001°C Removable Vessel & Bucket Bucket Filling: Manual Oxygen Filling: Automatic Combustion Vessel Washing: Manual Memory1000 Tests
M/S. PARR INSTRUMENT COMPANY, 211, 53RD STREET, MOLINE, IIIINOIS 61265, USA |
|
Thinking.
|
|
|
PARR ISOPERIBOL BOMB CALORIMETER
Roughness Checker Surtroni
ROUGHNESS CHECKER Surtroni 25
Model: Surtroni 25 Taylor Hobson Limited, England
Specification
|
Learning Objective
|
Learning Outcome
|
Tools Required
|
Safety Precaution |
Every component surface has some form |
Care & Safe |
Understanding Safe |
Soft Cleaning Cloth |
Apron |
of texture. It is due to structure and |
Operation of |
Operation of |
|
Soft Gloves |
manufacturing. These surfaces can be |
Roughness Checker |
Roughness Checker |
Alkaline Battery 9V |
Shoes |
broken down into three main categories: Surface Roughness, Waviness and Form. |
Assembling |
Define Roughness |
Mounting Bracket & Clamp |
|
Roughness Checker is used to quantify |
components for |
|
|
|
these parameters. |
Measurement |
Measure & Evaluate |
Extension Rod, Support |
|
Traverse Speed: 1mm/Sec |
|
Ra Value |
|
|
Cutoff Value: 0.25mm, 0.8mm and 2.5mm |
Measurement of |
|
Skid & Pick-up |
|
Resolution: Horizontal- 0.5mm (8mm), |
Surface Roughness |
Hands on Industrial |
|
|
1.0mm (>8mm)
|
|
Experience
Research and Analysis |
Desk Top Computer for Data Storage and analysis
|
|
ROUGHNESS CHECKER Surtroni 25
XRF Spectrometer
XRF SPECTROMETER
Model: Epsilon 1 PANalytical B.V. The Netherlands
Specification
|
Learning Objective
|
Learning Outcome
|
Tools Required |
Safety Precaution |
The Epsilon 1 X-Ray Fluorescence |
1. Calibration of |
Calibration, Operation |
1.Sample Cup |
Shoes |
Spectrometer is used for elemental |
Instrument |
and Care of XRF |
2.Sample Positioning Ring |
Apron |
analysis. The spectral X-ray |
2.Standard Sample |
|
3.P1 Cup set for Liquid |
Hand |
analysis of wide variety of materials can be done e.g. composites, metals, drugs, coins,
|
Preparation (solid, powder, liquid) 2.Care & Operation of XRF |
Tackling Unfamiliar Chemical Analytical Problems |
4.Spectro Membrane Polypropylene- thin film 6.0µm 5.Mylar Thin Film 3.6µm 6.P1 Assembly Tool |
Gloves |
animal feed with a wide variety of sample compositions from sodium to americium across the periodic table. It can handle a large variety of sample types, weighing a few 100 milligrams, to larger bulk samples: solids, pressed powders, loose powders, liquids, fused beads, slurries, granules, films and coatings. Also large and irregularly shaped objects with maximum dimensions of 15 x 12 x 10 cm (W x D x H) can be analyzed.
Make: PANalytical B.V. Lelyweg 1, 7602 EA Almelo
P.O. Box 13, 7600 AA Almelo The Netherlands |
3. Result Reporting
For: Diploma B.Sc./ M.Sc. B.Tech /M.Tech Research (PhD) |
Evaluating Information & Formulating Research Hypotheses
Analytical and Critical Thinking.
|
7.SMH cell-3
1. Powder Grinder 2. Press Pallet Compacter 3. Brush 4. Tissue Paper |
XRF SPECTROMETER